Electrolux EFP6411X Bedienungsanleitung Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
Technical Details
EFP 6440 EFP 6411
Dimensions (in cm):
Height 17,3 17,3
Width 59,8 59,8
Depth 29,5 -45 29,5 -45
Maximum absorbed power: 330 W 200 W
Motor absorption: 2 x 125 W 1 x 120 W
Lighting: 2 x 40 W 2 x 40 W
Length of the cable: 150 cm 150 cm
Electrical connection: 220-230 V 220-240 V
Subject to change without notice.
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the company responsible for the
transportation.
Damages, faults and eventually missing details
should immediately be reported to the retailer.
Take care of the packing materials so that small
children cannot play with them.
Fitting
The hood is to be mounted on the wall.
When installed, the hood must be not less than 50
cm. above electric burners or 65 cm. above gas or
mixed-fuel burners.
The hood can be installed above these heights but
for optimum performance it should be installed at
the distance quoted for the appropriate heat source.
Electrical connection (not for
UK)
Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be
connected to any standard power socket within
easy access.
Should it be necessary to provide a fixed
connection, the hood must only be installed by an
electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a
distance of at least 3 mm between contacts must
be provided.
Fixed connection of the appliance must only be
carried out by an authorised electrician.
Fig. 6 - Fitting
Min
65 cm
Min
50 cm
Electrical connection for UK
only
Safety warnings for the electrician
Connect the hood to the mains supply via a double
pole switch which has 3 mm minimum separation
between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow
must be connected to the terminal which is
marked with the letter E or by the earth symbol
( ), or coloured green or green and yellow;
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N or coloured black, -
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L or coloured red.
Seitenansicht 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare