The rating plate is on the bottom of the
hob.
Serial number ...........................
8.2 Built-in hobs
Only use the built-in hobs after you
assemble the hob into correct built-in units
and work surfaces that align to the
standards.
8.3 Connection cable
• The hob is supplied with the
connection cable.
• Replace the damaged mains cable only
with the spare parts cable. Speak to
your local Authorised Service Center.
WARNING!
All electrical connections
must be made by a qualified
electrician.
CAUTION!
Do not drill or solder the wire
ends. This is strictly
forbidden!
CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
One-phase connection - 230 V~ Two-phase connection - 400 V 2 ~ N
Green - yellow Green - yellow
N Blue and grey Blue and grey N
L Black and brown Black L1
Brown L2