9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G30/G31 (3B/P) 30/30 mbar 276 g/h
Gas replace‐
ment:
G20 (2H) 20 mbar 4,0 kW
G110 (1c) 8 mbar 4,0 kW
Electric sup‐
ply:
220-240 V ~ 50/60 Hz
Appliance cat‐
egory:
II2H3B/P
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Rapid 2,8 0,75 86 204
Auxiliary 1,0 0,33 50 73
9.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 3,0 0,75 119
Auxiliary 1,0 0,33 70
9.6 Gas burners for TOWN GAS G110 8 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 3,0 0,75 283
Auxiliary 1,0 0,33 142
10. ENVIRONMENTAL CONCERNS
Recycle materials with the symbol .
Put the packaging in relevant containers
to recycle it. Help protect the
environment and human health by
recycling waste of electrical and
electronic appliances. Do not dispose of
appliances marked with the symbol
with the household waste. Return the
product to your local recycling facility or
contact your municipal office.
*
www.electrolux.com16