12
Ignition HT Spark
Spark Generator Ispra Control's BF 50046 - 240V 0.6 YA T 120
Spark Gap Fixed
OVERALL DIMENSIONS
Width: 580 mm.
Depth: 510 mm.
Height: 88 mm.
Weight: 9,8 Kg.
Burner Dia. Tap By-pass Tap colour
1/100 mm
Auxiliary 28 Red/Red
Semi-rapid 32 Blue/Blue
Rapid 40 Black/Black
Aeration adjustment none
Instructions for the Installer
CUT OUT DIMENSIONS
Width: 550 mm.
Depth: 470 mm.
Thickness: 40 mm.
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 2.9 0.65 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.276 0.062 0.181 0.043 0.095 0.031
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.7 0.65 1.9 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 195 46.8 137 32.4 72 23.8
NOZZLE REFERENCE 86 40 71 32 50 28
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Rear Left Burner (semi rapid)
Heat Input 1.9 kW (6483 BTU/HR)
Front Left Burner (rapid)
Heat Input 2.9 kW Natural Gas (9895 BTU/HR)
2.7 kW L.P.G. (9212 BTU/HR)
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.
This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.
Engineer technical data
CLASS APPLIANCE: 3
APPLIANCE
CATEGORY: II2H3+
APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar
Rear Right Burner (semi rapid)
Heat Input 1.9 kW (6483 BTU/HR)
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)
Kommentare zu diesen Handbüchern