electrolux 13
Adaptation to different types of gas
A. Injectors replacement
• Remove the pan supports.
• Remove the burner's caps and
crowns.
• With a socket spanner 7 unscrew
and remove the injectors (Fig. 1), and
replace them with the ones required
for the type of gas in use (see table
«Gas burner» - page 11).
• Reassemble the parts, following the
same procedure backwards.
• Replace the rating label (placed near
the gas supply pipe) with the relevant
one for the new type of gas supply.
You can find this label in the package
of the injectors supplied with the
appliance.
Should the feeding gas pressure be
different or variable compared with the
required pressure, an appropriate
pressure adjuster must be fitted on the
gas supply pipe in compliance with the
rules in force.
B. Adjustment of minimum
level
To adjust the minimum level of the
burner, proceed as follows:
• Light the burner.
• Turn the knob on the minimum
position.
• Remove the knob.
• With a thin screwdriver, adjust the
by-pass screw (see Fig. 2).
If changing from natural gas to liquid
gas, completely tighten clockwise
the adjustment screw in.
If changing from liquid gas to natural
gas, undo the by-pass screw about
1/2 of a turn, until a small regular
flame is obtained.
• Finally check the flame does not go
out when quickly turning the knob
from the maximum position to the
minimum position.
))
))
)
))
))
)
This procedure can easily be carried
out, anyhow the hob has been
positioned or built in the working top.
Fig. 1
Fig. 2
By-pass screw