Gas hobsMod. EHG 682INSTRUCTION BOOKLETPlease read this instruction booklet before using the appliance35678-5601GB
10Important safety requirementsThis hob must be installed in accordance with the GasSafety (Installation and Use) Regulations (CurrentEdition) a
11It is important to install the elbow correctly, withthe shoulder on the end of the thread, fitted tothe hob connecting pipe.Failure to ensure the co
12Fitting the Hob into the worktopCarry out the building in of the hob as follows: put the seals supplied with the hob, on theedges of the cu
13Wiring diagramA. IGNITOR SWITCHB. IGNITOR UNITBLN01234220/240AFault findingPreliminary Electrical SystemsCheckBrownBlueGreenYellowGreenYellowBro
14Ignition System / Gas IgnitionYESCheck plug top fuse andreplace if necessaryCheck polarity andearth continuity ofsupply pointCheck earth continuityo
15CommissioningWhen the hob has been fully installed it will benecessary to check the minimum flame setting. To dothis, follow the procedure
CUSTOMER CAREElectrolux55-77 High StreetSloughBerkshire, SL1 1DZTel: 08705-950950© Electrolux Household Appliances Limited 2000Grafiche MDM - Forlì10
2Important Safety InformationYou MUST read these warnings carefully before installing or using the hob. If you needassistance, contact
31. Hob Top2. Rapid Burner3. Semi-rapid Burners4. Auxiliary Burner5. Control knob for back right burner (semi-rapid)6. Control knob for back left burn
4OperationBurner minimum maximumdiameter diameterLarge (rapid) 180 mm. 260 mm.Medium (semi-rapid) 120 mm. 220 mm.Small (Auxiliary) 80 mm. 160 mm.If
5Something Not Working? SYMPTOMn There is no spark when lighting the gasn The gas ring burns unevenly SOLUTIONu Check that the unit is plugged in
6For general enquiries concerning your Electroluxappliance or for further information on Electroluxproducts, please contact our Custome
7CHANNEL ISLANDSGUERNSEY Guernsey ElectricityPO Box 4Vale, GuernseyChannel Islands GY1 3ADJERSEY Jersey Electricity CompanyHaut De L’ormeRue De Haut
8MIDLANDSBIRMINGHAM 66 Birch Road EastWyrley Trading EstateWittonBirminghamB6 7DBBOURNE Pinfold RoadBournePE10 9HTBRIDGNORTH 68 St. Mary’s StreetBridg
9Ignition HT SparkSpark GeneratorIspra Control's BF 50046 - 230-240V 0.6 YA T 120Spark Gap FixedRear Left Burner (semi rapid)Heat Input 2.