8
Fig. 13
Fig. 14
Replacing the power cable
The power cable connection to the terminal block is of
the “Y” type: the flexible cable can only be replaced with
the use of a special tool that the service technicians
have.
When replacing the power cable only use H05V2V2-F
T90 type cables suitable for the load and operating tem-
perature. Also, the yellow/green earth wire must be
approx. 2 cm longer than the phase and neutral wires
(Fig. 13).
After connection, test the heating elements by operat-
ing them for about 3 minutes.
To open the terminal block cover and access the con-
nection terminals, proceed as follows:
● insert the tip of a screwdriver in the protrusions on the
visible side of the terminal block;
● press lightly and prise upwards (Fig. 14).
Fig. 15
TABLE 1 : BURNER SPECIFICATIONS
TYPE NOMINAL REDUCED NOMINAL
FEED
OF GAS BURNERS INJECTORS POWER POWER POWER
PRESSURE
1/100 mm kW kW mbar
m
3
/h
g/h G30 g/h G31
Rapid 119 3.0 0.65 0.286 - - 20
Semirapid 96 2.0 0.45 0.190 - -
Auxiliary 70 1.0 0.33 0.095 - -
Rapid 86 2.8 0.65 - 203 200 28-30/37
Semirapid 71 2.0 0.45 - 145 143
Auxiliary 50 1.0 0.33 - 72 71