14
Type of gas
Adjusted to natural gas: G20-20 mbar
Category and pressures
III1a2H3+ 20 mbar
Convertible to
Town gas - 8 mbar
Bottled gas - 28/37 mbar
Max. nominal load Q na H
S
:
Medium sized burner = 2,0 kW x 1
Large sized burner = 3,0 kW x 1
Total= 5,0 kW
FSD
The unit features fully-secured gas taps
(thermo-fuse).
H
S
= Top calorific value
Q = Nominal load
Voltage= 220-240 V
Ignition transformer= 50 HZ - 0,6 VA
Radio-noise reduction
This unit observes the current EEC-directive
on radio noise reduction.
This gas appliance is -approved and mar-
ked in accordance with the gas appliance
Directive (90/396/CEE), the low voltage
directive (73/23/CEE) and the EMC directive
(89/336/CEE incl. the agreed directive
changes.
Technical data
Kommentare zu diesen Handbüchern