System Unit
Tower Dimensions
18.27 x 8.62 x 30.28 in (46.4 x 21.9 x 76.9 cm)
Rack Dimensions
8.58 x 17.51 x 29.37 in (21.8 x 44.5 x 74.6 cm)
Tower Weight
Minimum:
66.14lb(30kg)
Maximum:
121.30lb (55kg)
Rack Weight
Minimum:
57.3lb(26kg)
Maximum:
112.4lb(51kg)
Input Requirements
(per power supply)
Range Line Voltage
100 to 120 VAC
200 to 240 VAC
BTU Rating
Maximum
For 1400W Power Supply: 5459 BTU/hr (at 200
VAC), 5459 BTU/hr (at 240 VAC), 5459 BTU/hr (at
240 VAC) for China Only
For 800W Power Supply: 3207 BTU/hr (at 100
VAC), 3071 BTU/hr (at 200 VAC), 3112 BTU/hr (at
240 VAC) for China Only
For 500W Power Supply: 1979 BTU/hr (at 100
VAC), 1911 BTU/hr (at 200 VAC), 1965 BTU/hr (at
240 VAC) for China Only
Power Specifications
Power Supply Output
Rated Steady-State Power
For 1400W Power Supply: 1400W (at 100 VAC),
1400W (at 240 VAC), 1400W (at 240 VAC)
For 800W Power Supply: 800W (at 100 VAC),
800W (at 240 VAC), 800W (at 240 VAC) input for
China only
For 500W Power Supply: 500W (at 100 VAC),
500W (at 240 VAC), 500W (at 240 VAC) input for
China only
Maximum Peak Power
For 1400W Power Supply: 1400W (at 100 to 127
VAC), 1400W (at 200 to 240 1VAC), 1400W (at 240
VAC) input for China only
For 800W Power Supply: 800W (at 100 to 127
VAC), 800W (at 200 to 240 1VAC), 800W (at 240
VAC) input for China only
For 500W Power Supply: 500W (at 100 to 127
VAC), 500W (at 200 to 240 VAC), 500W (at 240
VAC) input for China only
System Inlet
Temperature
Standard Operating
Support
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 20°C/hr
(36°F/hr). The upper limit and rate of change may
be limited by the type and number of options
installed. For approved hardware configurations,
the supported system inlet range is extended to
be: 5° to 40°C (41° to 104°F) at sea level with an
altitude derating of 1.0°C per every 175 m (1.8°F
per every 574 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft). The approved
hardware configurations for this system are listed
at the URL:
http://www.hp.com/servers/ashrae
.
For approved hardware configurations, the
supported system inlet range is extended to be:
5° to 45°C (41° to 113°F) at sea level with an
QuickSpecs