Electrolux EWM1000 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Waschmaschinen Electrolux EWM1000 herunter. EWM 1000 DIAGNOSTICS & FAULTFINDING Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - FAULTFINDING

1TSE-N / A.S. February 2002EWM 1000DIAGNOSTICS&FAULTFINDING

Seite 2

10TSE-N / A.S. February 2002Diagnostic modeComponent actuation 7Checked functions:• Tub leakage testActuated components:• Door lock• Main wash soleno

Seite 3

11TSE-N / A.S. February 2002Diagnostic modeComponent actuation 8Checked functions:• Draining• Spinning• Pressure switch level congruenceActuated comp

Seite 4 - Component actuation 1

12TSE-N / A.S. February 2002Diagnostic modeComponent actuation 9Not applicable to front-loaded machines(checks 3rd drum self-positioning )

Seite 5 - Component actuation 2

13TSE-N / A.S. February 2002Diagnostic modeReading the last alarm codeIf an alarm code is stored in theEEPROM, this will be shown inhexadecimal code

Seite 6 - Component actuation 3

14TSE-N / A.S. February 2002Diagnostic modeReading the last alarm codeIf an alarm code is stored in theEEPROM, this will be shown by2 flashing LEDs:C

Seite 7 - Component actuation 4

15TSE-N / A.S. February 2002ØCYCLE END shows the first digit of the alarm code (alarm family)ØSTART /PAUSE shows the second digitØth

Seite 8 - Component actuation 5

16TSE-N / A.S. February 2002Diagnostic modeReading the last alarm codeAn example: code E43LED CYCLE ENDLEDSTART/PAUSEOn / offTime(secs)ValueOn / off

Seite 9 - Component actuation 6

17TSE-N / A.S. February 2002Diagnostic modeCancel the last alarm codeØMachine in diagnostic mode, programme selector in position 10ØPress START/PAU

Seite 10 - Component actuation 7

18TSE-N / A.S. February 2002Diagnostic modeCancel alarm code vertical configurationØMachine in diagnostic mode, programme selector in position 10ØPr

Seite 11 - Component actuation 8

19TSE-N / A.S. February 2002Diagnostic modeExitØto exit the diagnostic mode, switch OFF the appliance.Øthen switch it ON, and switch it OFF AGAIN

Seite 12 - Component actuation 9

2TSE-N / A.S. February 2002Diagnostic modeAccessTo enter the diagnostic mode, press START/PAUSE and one option button simultaneously,and turn program

Seite 13 - Reading the last alarm code

20TSE-N / A.S. February 2002Alarms shown in the user modeØOnly the alarm family (first digit of the code)LED CYCLE ENDOn / offTime(secs)Value0.4 10.4

Seite 14

21TSE-N / A.S. February 2002Quick reading of alarm codesØThe last alarm can be read even if the machine is not in the diagnostic mode:ØPress START/

Seite 15

22TSE-N / A.S. February 2002Alarm code family 1:Water fillØE11: water fill problems in wash cycle (time-out expired)ØE13: water leakage

Seite 16

23TSE-N / A.S. February 2002Alarm code family 2:DrainingØE21: drain problems (time-out expired)ØE23: drain pump triac failureØE24: drain pump triac s

Seite 17 - Cancel the last alarm code

24TSE-N / A.S. February 2002Alarm code family 3:Pressure switchØE33: incongruency between antiboil and 1st level switches (longer than 3 se

Seite 18

25TSE-N / A.S. February 2002Alarm code family 4:Door lockØE41: door open (time-out expired)ØE42: door lock failureØE43: door lock triac failureØE44:

Seite 19

26TSE-N / A.S. February 2002Alarm code family 5:Motor circuitØE51: motor triac short circuitØE52: no tachometer signal from motorØE53: motor triac se

Seite 20 - Alarms shown in the user mode

27TSE-N / A.S. February 2002Alarm code family 6:Heating circuitØE61: insufficient heating in wash cycle (time-out expired) NOT S

Seite 21 - Quick reading of alarm codes

28TSE-N / A.S. February 2002Alarm code family 7:NTC sensorØE71: NTC sensor failure (value out of limits)

Seite 22 - Water fill

29TSE-N / A.S. February 2002Alarm code family 8:Programme selectorØE82: wrong selector reset position selectionØE83: wrong selector reading

Seite 23 - Draining

3TSE-N / A.S. February 2002Diagnostic modeAccess (vertical configuration)To enter the diagnostic mode, press the uppertwo pushbuttons on the left-han

Seite 24 - Pressure switch

30TSE-N / A.S. February 2002Alarm code family 9:ConfigurationØE93: machine configuration errorØE94: cycle configuration errorØE95: communication erro

Seite 25 - Door lock

31TSE-N / A.S. February 2002Alarm code family A:DSPØEA1: DSP (door self-positioning on top-loaded machines only) NOT SHOWN IN U

Seite 26 - Motor circuit

32TSE-N / A.S. February 2002Alarm code family B:Power supplyØEB1: power supply frequency out of limitsØEB2: power supply voltage too highØEB3: power

Seite 27 - Heating circuit

33TSE-N / A.S. February 2002Component Diagnostic Connector Identification

Seite 28 - NTC sensor

34TSE-N / A.S. February 2002Component Diagnostic J1 = Motor connectorJ1-1 to J1-2:full stator winding: 1 - 3 Ω(depending on type of motor)

Seite 29 - Programme selector

35TSE-N / A.S. February 2002Component Diagnostic J1 = Motor connectorJ1-1 to J1-3:half stator winding: 0.5 - 1.5 Ω(on machines with > 1400 rpm)(de

Seite 30 - Configuration

36TSE-N / A.S. February 2002Component DiagnosticJ1 = Motor connectorJ1-4 to J1-5: rotor winding: 1.5 - 3 Ω(depending on type of motor)

Seite 31 - Alarm code family A:

37TSE-N / A.S. February 2002 Motors

Seite 32 - Power supply

38TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesBIMETAL PTCDOOR LOCK !J2-4 to J6-2:door lock bimetalPTC about 1

Seite 33 - Connector Identification

39TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesINSTANTANEOUSDOOR LOCK !J2-4 to J6-2:solenoid +PTC protectorabou

Seite 34 - J1 = Motor connector

4TSE-N / A.S. February 2002Diagnostic modeComponent actuation 1Checked functions:• User interface functionalityActuated components:• all LEDs light i

Seite 35

40TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesINSTANTANEOUSDOOR LOCK !J2-5 to J6-2:bimetal PTCabout 1 kΩ)

Seite 36 - J1 = Motor connector

41TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesINSTANTANEOUSDOOR LOCK !J2-4 to J2-5:solenoid + PTC protector+ b

Seite 37 - Motors

42TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesALLDOOR LOCKSJ2-1 to J6-2:door switch,open or closed

Seite 38

43TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesJ2-1 to J2-2:“1st” level press.switch, open ifwater below “1st”l

Seite 39

44TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesJ6-1 to J2-2:antiboil level press.switch, open if waterbelow thi

Seite 40

45TSE-N / A.S. February 2002Component DiagnosticJ2, J6 = Door lock, Pressure switchesJ2-3 to J2-6:antiflood levelpress. switch (noton all models !),n

Seite 41

46TSE-N / A.S. February 2002Component DiagnosticJ3 = Solenoid Valves and Drain PumpJ3-2 to J3-5:prewash solenoid valveabout 3.75 kΩ

Seite 42

47TSE-N / A.S. February 2002Component DiagnosticJ3 = Solenoid Valves and Drain PumpJ3-6 to J3-7:main wash solenoid valveabout 3.75 kΩ

Seite 43

48TSE-N / A.S. February 2002Component DiagnosticJ3 = Solenoid Valves and Drain PumpJ3-1 to J3-4:drain pump motorabout 170 Ω

Seite 44

49TSE-N / A.S. February 2002Component Diagnostic J5 = NTC and TachogeneratorJ5-1 to J5-2:NTC sensor, about 6 kΩ at roomtemperature(see sensor charact

Seite 45

5TSE-N / A.S. February 2002Diagnostic modeComponent actuation 2Checked functions:• Water fill main wash compartmentActuated components:• Door lock• M

Seite 46

50TSE-N / A.S. February 2002NTC Characteristic

Seite 47

51TSE-N / A.S. February 2002Component Diagnostic J5 = NTC and TachogeneratorJ5-1 to J5-2:tachogenerator 65 to 540 Ω,depending on motor type.If motor

Seite 48

52TSE-N / A.S. February 2002 Motors

Seite 49 - J5 = NTC and Tachogenerator

53TSE-N / A.S. February 2002Component DiagnosticJ4 = Provision for Door Pilot LampJ4-1 to J4-2:door pilot lamp(only on few models !)

Seite 50 - NTC Characteristic

54TSE-N / A.S. February 2002Component DiagnosticAnd J7 ???J7 is the external serial interface:It may be used to connect the circuit board to acompute

Seite 51

6TSE-N / A.S. February 2002Diagnostic modeComponent actuation 3Checked functions:• Water fill prewash compartmentActuated components:• Door lock• Pre

Seite 52

7TSE-N / A.S. February 2002Diagnostic modeComponent actuation 4Checked functions:• Water fill fabric conditioner compartmtActuated components:• Door

Seite 53

8TSE-N / A.S. February 2002Diagnostic modeComponent actuation 5Not applicable to EWM1000 machines(checks 3rd solenoid valve)

Seite 54

9TSE-N / A.S. February 2002Diagnostic modeComponent actuation 6Checked functions:• HeatingActuated components:• Door lock• Main wash solenoid valve i

Kommentare zu diesen Handbüchern