Be sure to lay the drain hose downward for
smooth drainflow.
1
2
1 No trap allowed
2 Not to rise
Be careful not to allow the drain hose to
rise, form a trap or leave its end in water,
as shown below.
1
2
3
1 Not running wavy
2 No trap allowed
3 Not left in water
Coil thermal insulation around a drain hose
extension, if running in the room.
It is recommended to add an "intermediate
air vent" when the drain hose is extended
horizontally, or an "anti-back-flow air vent"
when the hose is exposed to high winds
on a high-rise building, for example. For
this purpose, employ a "T tube joint" (PVC-
made, commercially available) halfway in
the hose.
2
1
1 To drainage pit
2 Air vent (T tube joint)
Connecting the refrigerant pipes
Use pipes with thickness 0.8mm.
Connect the pipes for the indoor unit first
and then for the outdoor unit.
Bend the pipes carefully as not to damage
them.
Do not over tighten the tubes; it may be
deformed or damaged.
Use a torque wrench, when possible. See
the table below for the flare nut tightening
torque.
Flare nut tightening torque
Tube size Torque
Liquid side 1/4" 16±2N·m (1.6±0.2kgf·m)
Gas side 3/8" 38±4N·m (3.8±0.4kgf·m)
Flaring the pipe end
1. Cutting with a pipe cutter
Cut at a right angle.
2. Deburring
Allow no cuttings in the pipe.
3. Putting in the flare nut
4. Flaring
Flare processing dimensions (A) differ ac-
cording to the type of flare tool.