By-pass screw
FO 0392
Injectors replacement
Remove the pan supports.
Remove the burner's caps and
crowns.
With a socket spanner 7 unscrew
and remove the injectors, and replace
them with the ones required for the
type of gas in use.
Reassemble the parts, following the
same procedure backwards.
Replace the rating label (placed near
the gas supply pipe) with the relevant
one for the new type of gas supply.
You can find this label in the package
of the injectors supplied with the
appliance.
Should the feeding gas pressure be
different or variable compared with the
required pressure, an appropriate
pressure adjuster must be fitted on the
gas supply pipe, in compliance with the
rules in force.
Adjustment of minimum level
To adjust the minimum level of the
burners, proceed as follows:
Light the burner.
Turn the knob on the minimum position.
Remove the knob.
With a thin screwdriver, adjust the by-pass screw. If changing from natural
gas to liquid gas, completely tighten clockwise the screw, until a small regular
flame is obtained. If changing from liquid gas to natural gas unscrew about
1/4 turn the by-pass screw, until a small regular flame is obtained.
Finally check the flame does not go out when quickly turning the knob from
the maximum position to the minimum position.
This procedure can easily be carried out, anyhow the hob has been positioned
or built in the working top.
Adaptation to different types of gas
IMPORTANT - When the final connection has been made, it is
essential that a thorough leak test is carried out on the hob and
installation. Use some soapy water, never a flame.