14.4 Bypass diameters
BURNER
Ø BYPASS
1)
1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Oven 44
1)
Type of bypass depends on model.
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW‐
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0
0.72 / 0.75
1)
119
Semi-rapid
2.0 / 1.9
1)
0.43 / 0.45
1)
96
Auxiliary 1.0 0.35 70
Oven 2.7 0.90 120
Grill 1.9 - 108
1)
Type of bypass depends on model.
14.6 Gas burners for LPG G30 30 mbar
BURNER NORMAL
POWER kW
REDUCED
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 3.0 0.72 88 218.14
Semi-rapid 2.0 0.43 71 145.43
Auxiliary 1.0 0.35 50 72.71
Oven 2.7 0.90 80 196.33
Grill 1.9 - 71 138.16
14.7 Gas burners for LPG G31 30 mbar
BURNER NORMAL
POWER kW
REDUCED POW‐
ER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 2.6 0.63 88 185.68
Semi-rapid 1.7 0.38 71 121.40