8. TECHNICAL INFORMATION
Hob dimensions
Width: 594 mm
Length: 510 mm
Hob recess dimensions
Width: 560 mm
Length: 480 mm
Heat input
Triple Crown
burner:
4.0 kW
Semi-rapid burn-
er:
2.0 kW
Auxiliary burner: 1.0 kW
TOTAL POWER: G20 (2H) 20 mbar
= 9 kW
G30 (3+) 28-30
mbar = 654 g/h
G31 (3+) 37 mbar
= 643 g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible ca-
ble with non re-
wireable plug fit-
ted with a 3 amp
cartridge fuse
Gas connection: G 1/2 "
Category: II2H3+
Gas supply: G20 (2H) 20 mbar
Appliance class: 3
By-pass diameters
Burner Ø By-pass in
1/100 mm
Auxiliary 28
Semi-rapid 32
Triple Crown 56
Gas burners
BURN-
ER
NOR-
MAL
POWER
RE-
DUCED
POW-
ER
NORMAL POWER
NATURAL GAS
G20 (2H) 20
mbar
LPG (Butane/Propane)
G30/G31 (3+) 28-30/37
mbar
kW kW
inj.
1/100
mm
m³/h
inj.
1/100
mm
G30 G31
g/h g/h
Auxiliary 1.0 0.33 70 0.095 50 73 71
Semi-
rapid
2.0 0.45 96 0.190 71 145 143
Triple
Crown
4.0 1.4 146 0.381 98 291 286
9. ENVIRONMENT CONCERNS
Recycle the materials with the symbol
. Put the packaging in applicable
containers to recycle it.
Help protect the environment and human
health and to recycle waste of electrical
and electronic appliances. Do not dispose
appliances marked with the symbol
14
www.electrolux.com
Kommentare zu diesen Handbüchern