13
OVERALL
DIMENSIONS
Width: 580 mm.
Depth: 500 mm.
Height: 88 mm.
Weight: 11 Kg.
Instructions for the Installer
CUT OUT
DIMENSIONS
Width:550 mm.
Depth: 470 mm.
Thickness: 30 mm.
SUPPLY CONNECTIONS
This hob is designed to be connected to 230-240 V
(50Hz) electricity supply.
The hob has a terminal block which is marked as
follows:
L - Live terminal
N - Neutral terminal
or E - Earth terminal
The cable used to connect the hob to the electrical
supply must be 6mm, PVC twin and earth, and fused
to 30amp.
It is necessary that you install a double pole swith
between the hob and the electricity supply (mains),
with a minimum gap of 3mm between the swith
contacts and of a type suitable for the required load in
compliance with the current rules.
The swith must not break the yellow and green earth
cable at any point.
Engineers technical data
Heating elements Ratings
Normal front left Hotplate Ø 180 mm 1570 W
Normal back left Hotplate Ø 145 mm 1040 W
Rapid front right Hotplate Ø 145 mm 1570 W
Rapid back right Hotplate Ø 180 mm 2090 W
Total rating 6270 W
Important safety requirements
This hob must be installed in accordance with the IEE
Wiring Regulations (Current Edition).
Detailed recommendations are contained in the
following British Standards Codes Of Practice: B.S.
6172/ B.S. 5440, Par. 2 and B.S. 6891 Current
Editions.
Location
This hob has been registered as a "Class X" appliance
according to Fire Risk Regulations. Minimum
distances detailed below must be observed. The hob
may be located in a kitchen, a kitchen/diner or bed
sitting room, but not in a bathroom or shower room.
Before making the cut out in the worktop ensure that
there is a minimum distance of 55 mm. between the
rear edge of the hob and the wall. A minimum
distance of 100 mm. must be left between the side
edges of the hob and any adjacent cabinets or walls.
The minimum distance combustible material can be
fitted above the hob in line with the edges of the hob
is 400 mm. If it is fitted below 400 mm. a space of 50
mm. must be allowed from the edges of the hob.
The minimum distance combustible material can be
fitted directly above the hob is 700 mm.
650 mm
400 mm
400 mm
100 mm
50 mm
50 mm
55 mm
600 mm
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITH A COOKER HOOD ABOVE
FO 0813
700 mm
400 mm
100 mm
400 mm
50 mm
55 mm
50 mm
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE HOB
WITHOUT A COOKER HOOD ABOVE
FO 0812