Electrolux EHG9830X Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
A
A)
The by-pass screw
If you change from natural gas G20 20
mbar to liquid gas, fully tighten the by-
pass screw in.
If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2
of a turn for Triple Crown burner).
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
There is a risk of fire when the appli-
ance is in connection with an extension
cable, an adapter or a multiple connec-
tion. Make sure that the ground con-
nection agrees with the standards and
regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue neu-
tral cable to the terminal with a letter "N"
on it. Connect the brown (or black) phase
cable to the terminal which has a letter
"L". Keep the phase cable connected at
all times.
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building In
min. 45 mm
min. 650 mm
830 mm
min. 100 mm
40 mm
480 mm
10 mm
27 mm
27 mm
A
3 mm
A
B
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
12
www.electrolux.com
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 31 32