
BUILT-IN APPLIANCES
• Only use the built-in appliances after you
assemble the appliance into correct built-
in units and work surfaces that align to
the standards.
ELECTRICAL CONNECTION
• Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must include
an isolating device with at least a 3 mm-
contact separation to enable a simultane-
ous and all-pole cut off from the mains
(according to NIN SEV 1000).
ASSEMBLY
min.
50mm
min.
500mm
490
+1
mm
560
+1
mm
R 5mm
55mm
min.
28 mm
TECHNICAL INFORMATION
Model GK58PCN Prod.Nr. 949 594 356 00
Typ 58 AAD 55 XO 400 V 50 Hz
Made in Germany
Ser.Nr. .......... 7.1 kW
ELECTROLUX
Cooking zones power
electrolux 7
Kommentare zu diesen Handbüchern