21 ENGLISH
The following events may occur during
normal operation.
1. Protection of the air conditioner
Compressor
The compressor can’t restart for
3-4 minutes after it stops.
Anti-cold air (Cooling and heating
models only)
The unit is designed not to blow
cold air on HEAT mode, when the
indoor heat exchanger is in one of the
following three situations and the set
temperature has not been reached.
A) When heating has just started.
B) Defrosting.
C) Low temperature heating.
The indoor or outdoor fan stop running
when defrosting (Cooling and heating
models only).
Defrosting (Cooling and heating
models only)
Frost may be generated on the outdoor
unit during heat cycle when outdoor
temperature is low and humidity is high
resulting in lower heating eciency of
the air conditioner.
During this condition air conditioner
will stop heating operation and start
defrosting automatically.
The time to defrost may vary from 4 to
10 minutes according to the outdoor
temperature and the amount of frost
built up on the outdoor unit.
2. A white mist coming out from the
indoor unit
A white mist may generate due
to a large temperature dierence
between air inlet and air outlet
on COOL mode in an indoor
environment that has a high relative
humidity.
A white mist may generate due to
moisture generated from defrosting
process when the air conditioner
restarts in HEAT mode operation
after defrosting.
3. Abnormal noise of the air
conditioner
You may hear a low hissing sound
when the compressor is running or
has just stopped running. It is the
sound of the refrigerant flowing or
coming to a stop.
You can also hear a low “squeak”
sound when the compressor
is running or has just stopped
running. This is caused by heat
expansion and cold contraction of
the plastic parts in the unit when the
temperature is changing.
A noise may be heard due to louver
restoring to its original position when
power is turned on.
4. Dust is blown out from the indoor
unit
This is a normal condition when the air
conditioner has not been used for a
long time or during rst use of the unit.
5. A peculiar smell comes out from
the indoor unit
This is caused by the indoor unit giving
o smells permeated from building
material, from furniture, or smoke.
6. The air conditioner turns to FAN
only mode or stop operation from
COOL or HEAT mode
When indoor temperature reaches the
temperature setting on air conditioner,
the compressor will stop automatically,
and the air conditioner turns to FAN
only mode or stop operation. The
compressor will start again when the
indoor temperature rises on COOL
mode or falls on HEAT mode.
7. The air conditioner runs Anti-
mildew function after turning o the
unit.
When turning o the unit under COOL
and DRY mode, the air conditioner will
run for 2 minutes to anti-mildew, then
stop the operation and turn o the unit
automatically.
Dripping water may generate on the
surface of the indoor unit when cooling
in a high relatively humidity. Adjust
the horizontal louver to the maximum
14. OPERATION TIPS