SERVICE- INSTRUCTIONPublications-No.:599 47 22-58/4replaces 599 47 11-18/1T.D. RS 05/2000Language: EnglishAES II- Absorption Refrigerators(only for bu
Cause 3: After the lifting magnet drops, the AES again tries to ignite and then goes to a fault after 25 seconds. Is the thermoelement on the thermoc
6.0 Wiring Diagram11
127.0 Spare Parts Numbers for the Functional PartsThermocurent adapter 295 1956-20/6Ignition fuse 295 1157-10/2Hexagon nut 280 1043-02/3AESII-electron
138.0 Bulletins
16Publication-No.: 599 4721-91/7 / Service 99.02.03 B.O./K.V.
9.0 Operation of AES II with solar charging regulatorsOperation of Electrolux refrigerators with AES II control and solar charging regulators.It is cu
182. Connection diagram (shared connection for battery and on-board power supplyon- board batterySolar charging regulatorAES has 12V level: refrigerat
19Electrolux Siegen GmbHIn der Steinwiese 16D-57074 SiegenTel.: 0271 / 692-0Fax.: 0271 / 692 - 300
Table of Contents Page1.0 Model Description 32.0 AES II System Function 32.1 Priorities 32.2 Switchover Times / Time Delays 32.3 Low Voltage Operation
1.0 Model Description2.0 AES II System FunctionAn AES II refrigerator independently selects between the possible energy sources of 230 V, 12 V, and ga
2.3 Low Voltage OperationThe so-called "low voltage gas operation" is an exception. If the electrical power supply voltagein 230-V or 12-V
3.0 Technical Descriptions3.1 Block DiagramThe following diagram shows the AES II system components:5Display ModulPower ModulSolar input230 V~12 V -D+
3.2 Power Module Connections6Connection Type DefinitionP1 I/ O Connection cable display/ power moduleP2 I Temperature sensorP3 I/ O ReigniterP4 O Lift
3.3 Display ModuleThe display module is located on the control frontplate of the AES II refrigerator.You must operate the power switch (A) to turn the
3.4 Power Module The power module (A) is located on the backside ofthe refrigerator. A multicore cable connects thepower module and the display modul
a) PreparationsThe AES II device must be connected to a 230-V supply line and a 12-V supply. You must con-nect a gas cylinder and open the gas supply