Electrolux EXD16DN3W Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
7 ENGLISH
Make sure to direct airow at the wet
clothes shown as picture below.
For thick and heavy wet clothes may
not get the best effective dehumidica-
tion.
CAUTION!
Do not cover the air outlet of the
unit with clothes. It may cause
excessive heat, re or failure
of unit.
Do not place the wet clothes on
the top of the unit and do not
make the water drop into the
unit. It may cause electric shock,
creepage or failure of unit.
4.8 How to Use Timer Function
The TIMER function enables you to ei-
ther Delay Start or Delay Stop the unit in
the choice from 0.5 hour to 24 hours.
When the unit is on, rst press the Timer
button, the Timer Off indicator light il-
luminates. It indicates the Auto Stop pro-
gram is initiated. Press it again the Time
On indicator light illuminates. It indicates
the Auto Start is initiated.
Press or hold the
or pad to change
the Auto time by 0.5 hour increments, up
to 10 hours, then at 1 hour increments up
to 24 hours. The control will count down
the time remaining until start.
The selected time will register in
5 seconds and the system will automati-
cally revert back to display the previous
humidity setting.
When the Auto start & Auto stop times
are set, within the same program se-
quence, TIMER ON OFF indicator lights
illuminate identifying both ON and OFF
times are now programmed.
Turning the unit ON or OFF at any time
or adjusting the timer setting to 0.0 will
cancel the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.
NOTE:
Before entering TIMER setting, make
sure power is being supplied to the unit.
Before entering TIMER setting, make
sure pressing HUMIDITY or button
sets one desired room humidity rst.
4.9 Fault Codes
AS- Humidity sensor error--Unplug the
unit and plug it back in. If error repeats,
call for service.
ES- Temperature sensor error-- Unplug
the unit and plug it back in. If error re-
peats, call for service.
P1- Unit is defrosting-- Allow the unit time
to automatically defrost. The protection
will clear after the unit self defrosts.
P2- Bucket is full or bucket is not in right
position-- Empty the bucket and replace
it in the right position.
E3- Unit malfunction-- Unplug the unit
and plug it back in. If error repeats, call
for service.
EC- Refrigerant leakage detection-- With
this new technology, the display area will
appear EC when the unit detects refriger-
ant leakage,call for service.
4.10 Removing collected water
There are two ways to remove collected
water.
4.11 Use the bucket
When the unit is off, if the bucket is full,
the unit will beep 8 times and the Full
indicator light will ash, the digital display
shows P2.
When the unit is on, if the bucket is full,
the compressor turns off and the fan
turns off after 30 seconds for drying the
water of the condenser, then the unit will
beep 8 times and the Full indicator light
will ash, the digital display shows P2.
Follow the step below to remove the col-
lected water from the bucket:
Seitenansicht 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 87 88

Kommentare zu diesen Handbüchern

Keine Kommentare