Connectingthe GreenApplianceWireto a GroundedSupply Wire
or a GroundedColdWaterPipe=WhereLo_l CodesPermit.
1 Separate the green and white appliance wires.
2 Connect the white appliance wire to the neutral (white) supply wire in the
junction box.
3 Connect the black appliance wire to the black (L1) power supply wire in the
junction box.
4 Connect the red appliance wire to the red (L2) power supply wire in the
junction box.
5 Connect the green appliance wire to a grounded supply wire in the junction
box or to a grounded cold water pipe.
6 If connecting to a grounded cold water pipe, a separate copper grounding
wire (No. 10 minimum) must be connected to a grounded cold water pipe
by means of a clamp and then to an external grounding connector screw.
Figure 16
Cable from
power supply
Junction
box
RED I WHITE
WHITE
GREE BLACK
_Wire nut
(4 places)
Conduit from
appliance
No. 10 (minimum)
copper grounding wire
No 4_
copper wire
Metal
Connecting the appliance ground to a grounded junction box wire
or grounded cold water pipe