• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the ad-
justment screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• There is a risk of fire when the appli-
ance is in connection with an extension
cable, an adapter or a multiple connec-
tion. Make sure that the ground con-
nection agrees with the standards and
regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
To prevent contact between the cable
and the appliance below the hob use the
clamps which are on the side of the cabi-
net.
A
A)
Rigid copper pipe or flexible pipe of
stainless steel
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building in
30 mm
55 mm
40-50 mm
min. 650 mm
490 mm
min. 450 mm
270 mm
If several 30 cm hobs are to be installed
side by side into the same cut out, an as-
sembly kit including a support side brack-
et and supplementary seals is available at
our Service Centres. The relevant installa-
tion instructions are supplied within the kit
package.
270
+1
mm
R 5mm
min.
55mm
490
+1
mm
12
www.electrolux.com