14.2 Technical data
Dimension mm
Height 855
Width 600
Depth 600
Total electricity power 20.6 W
Appliance class 1
14.3 Other technical data
Appliance category: II2H3B/P
Gas original: G20 (2H) 20 mbar
Gas replacement: G30/G31 (3B/P) 30/30 mbar
14.4 Bypass diameters
BURNER
Ø BYPASS
1)
1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Rapid 42
Oven 44
1)
Type of bypass depends on model.
14.5 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POW-
ER kW
REDUCED POWER kW INJECTOR MARK
1/100 mm
Rapid 3.0
0.72 / 0.75
1)
119
Semi-rapid
2.0 / 1.9
1)
0.43 / 0.45
1)
96
Auxiliary 1.0 0.35 70
Oven 2.7 0.90 120
Grill 1.9 - 108
1)
Type of bypass depends on model.
14.6 Gas burners for LPG G30 30 mbar
BURNER NORMAL
POWER kW
REDUCED
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 3.0 0.72 88 218.14
ENGLISH
23
Kommentare zu diesen Handbüchern