Electrolux EKK603504X Bedienungsanleitung Seite 38

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 84
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 37
Gas burners
BURNER
NORMAL
POWER
RE-
DUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) - 20 mbar
LPG
(Butane/Propane) G30/31-30
mbar
kW kW
inj. 1/100
mm
m³/h
inj. 1/100
mm
g/h
G30 G31
Auxiliary
burner
1,0 0,33 70 0,095 50 72 71
Semi-rap-
id burner
2,0 0,45 96 0,190 71 145 143
Rapid
burner
3,0 (nat.
gas)
2,8 (LPG)
0,75 119 0,286 86 204 200
Gas burners G20 13 mbar - only Russia
BURNER NORMAL
POWER
REDUCED
POWER
NORMAL POWER
NATURAL GAS
G20 (2H) 13 mbar
kW kW inj. 1/100 mm m³/h
Auxiliary burner 0.9 0.33 80 0.095
Semi-rapid burner 1.4 0.45 105 0.148
Rapid burner 1.9 0.75 120 0.201
Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with
the regulation in force. If you use flexible
metallic pipes, be careful they do not come
in touch with mobile parts or they are not
squeezed.
Flexible nonmetal pipes connection
If it is possible to easily control the connec-
tion in its full area, you can use a flexible
pipe. The flexible pipe must be tightly at-
tached by clamps.
Installation: use the rubber pipe holder. Al-
ways engage the gasket. Then continue
with the gas connection. The flexible pipe is
prepared for apply when:
it can not get hot more than room tem-
perature, higher than 30°C;
it is no longer than 1500 mm;
it shows no throttles;
it is not subject to traction or torsion;
it does not get in touch with cutting
edges or corners;
it can be easily examined in order to
check its condition.
The control of preservation of the flexible
pipe consists in checking that:
it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
the material is not hardened, but shows
its correct elasticity;
the fastening clamps are not rusted;
expired term is not due.
If one or more defects are visible, do not re-
pair the pipe, but replace it.
Important! When installation is complete,
make sure that the seal of each pipe fitting
is correct. Use a soapy solution, not a
flame!
The gas supply ramp is on the rear side of
the control panel.
Warning! Before gas connection
disconnect the mains plug from the
mains socket or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
38 electrolux