31
Fig. 17
Injectors replacement
1) Remove the pan supports.
2) Remove the burner's caps and crowns.
3) With a socket spanner 7 unscrew and remove the
injectors (Fig. 18), and replace them with the ones
required for the type of gas in use (see table 2).
4) To adapt the appliance to town gas, after installing the
proper injectors, fit the grid filter A (Fig. 19) on the
semi-rapid and auxiliray burner injectors.
5) Reassemble the parts, following the same procedure
backwards.
6) Replace the rating label (placed near the gas supply
pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.
Should the feeding gas pressure be different or variable
compared with the required pressure, an appropriate
pressure adjuster must be fitted on the gas supply pipe,
in compliance with the rules in force.
Fig. 18
FO 0795
FO 0392
Fig. 19
FO 0465
To adapt the appliance to a different kind of gas from the
one the appliance has been set for, follow the instructions
below in their order.
Replacement of rubber pipe
holder (Fig. 17) LPG preset range
To set the appliance ready for use with LPG, fit the rubber
pipe holder A.
To set the range ready for natural gas, fit the rubber pipe
holder «B» (supplied with the appliance). Always insert
the gasket «C» between the feeding pipe and the rubber
pipe holder.
Adaptation to different types of gas