Nominal Reduced Nominal Power Fedding
Type of Gas Burner Injector Power Power Pressure
1/100 mm kW kW mbar
Ultra-rapid 95 3,8 1,2 - 274
Semlrapid 71 2,0 0,45 - 144 28 - 30/37
Auxiliary 50 1,0 0,33 - 72
Oven 82 3,0 1,0 - 216
Ultra-rapid 145 4,0 1,2 0,381 -
Semlrapid 96 2,0 0,45 0,190 - 20
Auxiliary 70 1,0 0,33 0,095 -
Oven 116 3,0 1,0 0,286 -
Ultra-rapid 330 3,65 1,2 0,827 -
Semlrapid 210 2,0 0,45 0,453 - 8
Auxiliary 142 1,0 0,33 0,227 -
Oven 254 3,0 1,0 0,680 -
CHARACTERISTICS OF BURNERS AND INJECTORS
Tab. 1
L.P.G.
Natural
Gas
To w n G as
m
3
/h g/h
Electrical connection
The unit is preset to work with a voltage of single phase
230 V. Connection must be carried out in compliance
with the rules in force.
Before making the connection make sure that :
- the energy power available in the user's house is
sufficient for the normal supply of this appliance (see
rating plate);
- the unit is correctly connected to earth through a
suitable plug and according to the installation country
Laws;
- the socket or the omnipolar switch used for the
connection are easily accessible after the appliance
has been positioned.
Fit a proper plug on the connection cable. The plug has
to be able to withstand the load and be connected to an
adequate socket.
If you want a direct connection to the mains, you must
interpose an omnipolar switch with a minimum opening
between contacts of 3 mm, between the unit and the
mains, complying with the existing regulations.
The brown live wire (originating from the clamp of the
cooker junction box) must always be connected to the
phase of the mains supply.
In any case, the supply cable must be positioned in such
a way as it doesn't reach in any point a temperature
higher by 50°C than the room temperature.
Should the supply cable need to be replaced, only type
H05RR-F cables must be used and the yellow/green earth
wire must be about 2cm longer than the live and neutral
ones (Fig. 25).
After the connection, test the heating elements for about
3 minutes to ensure that they are working correctly.
Ground (yellow - green)
Neutral
wire
Phase
FO 0480
Fig. 25
The manufacturer refuses any responsability in
cases where normal safety measures are not
observed.