18
TYPE BURNER INJECTORS NOMINAL REDUCED NOMINAL FEEDING
OF GAS POWER POWER POWER PRESSURE
1/100 mm kW kW m
3
/h g/h mbar
Triple-crown 136 3,5 1,20 0,333 -
Ultra-rapid 121 3,2 0,65 0,305 -
Rapid 119 3,0 0,65 0,286 - 20
Semi-rapid 96 2,0 0,45 0,190 -
Auxiliary 70 1,0 0,33 0,095 -
Fish kettle burner 119 3,0 0,85 0,286 -
Triple-crown 93 3,5 1,20 - 252
Ultra-rapid 88 3,2 0,65 - 231
Rapid 86 2,8 0,65 - 201 28-30/37
Semi-rapid 71 2,0 0,45 - 144
Auxiliary 50 1,0 0,33 - 72
Fish kettle burner 86 2,8 0,85 - 230
Triple-crown 235 3,2 1,20 0,666 -
Rapid 235 2,9 0,65 0,604 - 12,5
Semi-rapid 180 2,0 0,45 0,417 -
Auxiliary 134 1,1 0,33 0,229 -
NATURAL
GAS
(Methane)
Technical data
LIQUID
GAS
(But./Prop.)
Specifications for hob burners and injectors
Electric Oven Heating elements rating
Bottom heating element 1,200 W
Top heating element 1,000 W
Electric Grill element 1,800 W
Oven Light 25 W
Turnspit 4 W
Oven Capacity 49,2 dm³ (appliances with electric oven)
46 dm³ (appliances with gas oven)
TYPE BURNER INJECTORS NOMINAL REDUCED NOMINAL FEEDING
OF GAS POWER POWER POWER PRESSURE
1/100 mm kW kW mbar
m
3
/h g/h
Oven burner 116 3,0 1,0 0,286 - 20
Grill burner 111 2,5 - 0,238 -
Oven burner 82 3,0 1,0 - 216 28-30/37
Grill burner 74 2,3 - - 166
NATURAL
GAS
(Methane)
LIQUID
GAS
(But./Prop.)
Specifications for oven burners and injectors
Electric Plate: Ø 180 mm - 1500 W
Appliance Class 1 and Class 2, Sub-Class 1
Category: II2H3+
(Appliance set for use with gas: Liquid gas G30-G31 (28-30/37 mbar)
Voltage tension: 230 V ~ 50 Hz
Plates and oven burners don't need regulation of primary air. Appliances should be installed in compliance with the local
regulations. Whereas pressure regulators are provided for appliances, they should comply with the rules in force.