TECHNICAL INFORMATION
FOR THE INSTALLATION
The installation and regulations shall be carried out by
qualified technicians only. After removing external packaging
and inside packing of movable parts, make sure of the
integrity of the appliance. In case of doubts do not use the
appliance and turn to qualified technicians.
Never leave packing components (carton, bags, foamed
polystyrene, nails.....) within the reach of children as they
represent potential dangers.
ASSEMBLY OF ADJUSTABLE LEVELLING FEET
Remove the packaging of the cooker. Assemble the feet
which are in the accessories kit, fitting them in the proper
fixed seats placed on the four corners of the cooker.
(fig. 16 – fig. 16/a). Align or level the cooker with other
furniture by adjusting the foot.
Fig. 16
GB 7
Fig. 16/A
REMARKS FOR THE INSTALLATION
The installation shall be carried out in compliance with the
national rules in force. Install the appliance in a well-aired
room. Check that the flux of the gas meter and the diameter
of the ducts have enough capacity for all the appliances and
that the connectors are water-tightness. The gas cookers
belong to Class I and therefore they shall not be put closer
to furniture. The walls next to the cooker shall be resistant
to a temperature of 75° C. (fig. 17) or covered with insulating
material. The cooker shall be installed at a distance of 20
mm from the walls and the cook-top 650 mm from the
suspended wall unit (fig. 17/a). The gas cookers belong to
class II can be lean agains the walls ( fig.17/b )
50 mm Min
650 mm Min
5 mm Min
CLASS II under Class I
Type Y
Dimensions
shown apply
to BOTH
sides of the
appliance
Applies
to base
&wall units
(if fitted)
Fig. 17/b
ROOMS VENTILATION
Attention: this appliance can be installed and used only
in constantly ventilated rooms according to the national
rules in force. The right functioning of the cooker is ensured
by the installation in a constantly ventilated room. The flow
of air for a regular gas combustion and ventilation shall not
be less than 20 m
3
. The natural influx of air shall be directly
from the outside through openings on the wall of the room
with a cross section of at least 100 cm
2
. These openings
shall be made in a way that can’t be clogged. It is allowed
the indirect airing through the extraction of air from adjacent
rooms (fig. 18) in compliance with the national regulations
in force.
ATTENTION:
The section of the ventilation opening of a cooker with
burners not fitted with safety thermocouple should be
at least 200 cm
2
.
POSITIONING
The gas cookers shall discharge smokes and gases from
combustion by means of hoods connected to chimneypots,
flues or directly outside. In absence of a hood it is permitted
the use of a ventilator installed on a window or on a wall to
the outside, which shall be operate simultaneously with the
appliance on condition that the national rules in force are
complied with.
Wider opening
between door
and floor
Fig. 18
CONNECTION TO THE GAS SYSTEM
Important: the installation shall be made according to the
national rules in force. Install the appliance in a well-ventilated
room; check that the capacity of the gas meter and the
hosepipes diameter are enough to supply power to all
appliances connected. Do not forget to install, upwards
the appliance, a gas cock of at least 1/2”, visible and
reachable.
Before connecting the appliance check the data reported
on the plate placed inside the chafing dish door or on the
back of the cooker reporting the type of gas, pressure and
capacity of the cooker.
Connection to canalized gas system: the cooker shall be
connected as indicated (fig. 19), by using:
- non-flexible steel metal pipe, copper pipe, flexible stainless
steel hosepipe, rubber flexible hosepipe, the hosepipes.
Shall be in compliance with the national rules in force. In
case of natural gas the supply pipe shall be put on the big
tubeholder (B) after screwing and taking away the reduction
unit (A) (liquefied gas tubeholder) (fig. 19.)
CONNECTION TO LIQUEFIED GAS-CYLINDER SPACE
The cookers with support for cylinders are regulated for
being used with LPG.
The support cylinder space is 620 mm high and 325 mm
wide and can contain standard cylinders of 10 kg.
50 Min
650 Min
20 Min
25 cm60 cm
Fig. 17 Fig. 17/A