Page 5
5
3. Installation
3. Installation3. Installation
3. Installation
Caution!!
Caution!! Caution!!
Caution!! The connection to the 230 Volt network as well as the entire installation of the exhaust hood
must be at absolute zero potential
at absolute zero potential at absolute zero potential
at absolute zero potential and conducted by a professional.
1. Workflow:
Carry the middle of the cooktop to
middle of the cooktop to middle of the cooktop to
middle of the cooktop to the ceiling.
2. Workflow:
Draw four drill holes on the ceiling and then drill the four holes. (Sketch 1 = IH EFA 1020.1;
Sketch 2 = IH EFA 1030)
3. Workflow:
Take four dowels, four hanger bolts and four decorative discs from the accessories kit. Insert
the four dowels, screw in the four hanger bolts, and screw the four decorative discs onto the
hanger bolts.
4. Workflow:
Now unpack the hood body.
5. Workflow:
Thread the cable suspension with the cable clamp from above into the hood body. Screw the
cable clamp into the mounting and secure with the set screw. One mounting per cable suspension.
6. Workflow:
Now screw the four wire cables with the cable supports onto the hanger bolts. Now the steel
cable can get twisted but it will ‘untwist‘ during workflow 7.
7. Workflow:
The wire cable relaxes and the length of the steel cable can be varied by exerting pressure
onto the cable clamp. The hood can be aligned using a water level.
8. Workflow:
Fasten the power cord of the hood to the feed line on site.
9. Uncover the hood after installation only so that no dirt particles can reach the top of the hood.
The unit can be uncovered again only once the kitchen has been completely set up and the
final cleaning has taken place.
Skizze 1 Skizze 2