Anti-cold air function
In HEAT mode, the indoor fan will not
operate in order to prevent cold air from
blowing out if the indoor heat exchanger
does not reach a certain temperature in
one of the following situations:
WHEN©THE©HEATING©OPERATION©STARTS
WHEN©THE©DEFROSTING©OPERATION©IS©
kNISHED
WHEN©HEATING©AT©LOW©TEMPERATURE
Gentle breeze
The indoor unit may blow gentle breeze
and the horizontal louvre rotates to a
certain position in one of the following
situations:
)N©(%!4©MODE©THE©COMPRESSOR©DOES©
not start operation after switching on
the unit.
)N©(%!4©MODE©THE©TEMPERATURE©
reaches the set value and the
compressor has stopped operation
for 1 minute.
Opetaring temperature range
The operating temperature range for
cooling-only units is -15-(+48)˚C. The
operating temperature range for heat-
pump units is -20-(+24)˚C.
Tip for energy saving
$O©NOT©OVERCOOL©OR©OVERHEAT©3ETTING©
the temperature at a moderate level
helps energy saving.
#OVER©WINDOWS©WITH©A©BLIND©OR©A©
curtain. Blocking sunlight and air from
outdoor is favorable for cooling.
#LEAN©AIR©kLTERS©EVERY©TWO©WEEKS©
Clogged air filters lead to inefficient
operation and energy waste.
Tip for relative humidity
)F©THE©UNIT©IS©OPERATED©IN©AN©AREA©WITH©
a relative humidity of more than 80%
for a long time, condensate may drip
from the indoor unit.
Installation notes
.OT©FOLLOWING©THE©INSTRUCTIONS©CAN©
cause personal injury and/or property
damage.
.OT©FOLLOWING©THE©INSTRUCTIONS©CAN©
cause the unit to fail.
,ET©THE©UNIT©BE©INSTALLED©BY©AN©
authorised service centre.
,ET©THE©UNIT©BE©INSTALLED©IN©COMPLIANCE©
with local and governmental
regulations.
,ET©THE©UNIT©BE©INSTALLED©ACCORDING©TO©
the instructions from this manual.
&IRST©CONTACT©AN©AUTHORISED©SERVICE©
centre before relocating an already
installed unit
$ISCONNECT©POWER©BEFORE©WORKING©ON©
the unit.
,ET©THE©MAINS©CABLE©BE©REPAIRED©BY©AN©
authorised service centre or qualified
technician for units with Y-attachment.
4HE©MAINS©PLUG©MUST©REMAIN©
accessible after installation.
+EEP©SUFkCIENT©DISTANCE©BETWEEN©
the interconnection cable and the
Indoor side (°C) Outdoor side (°C)
Max. cooling 32 48
Min. cooling 21 -15
Max. heating 27 24
Min. heating 20 -20