10
11.4 Connection of gas supply
(The following instructions refer in the main to coolers
manufactured in the United Kingdom. For other
countries please refer to your supplier.)
Always connect in the following sequence:
GAS BOTTLE → PRESSURE-REGULATOR →
→ APPLIANCE.
To connect the appliance to the pressure-regulator an
APPROVED GAS TUBING should be used. This should
be minimum in length - have an inside dimension of
8mm and be marked BS3212/2/8.
The pressure-regulator must be compatible for Propane
11 in (28 mbar).
To connect the pressure-regulator to the gas bottle, the
valve of the gas bottle must be closed. After connecting
the pressure regulator to the bottle by srewing, connect
the two ends of the tubing to the nipples and secure
them with the two hose clipses. (Figure 11).
When fitting the connection to the gas inlet of the
appliance (Figure 11), hold the counterpart to avoid
straining and possibly damaging.
The gas bottle ( Propane, red bottle) may only be
used in an upright position and particular care must
be taken every time the appliance is connected to
the gas bottle to ensure that there are no leaks, that
the tubing (rubber hose) is not under tension or
kinked, and that it is not in contact with hot
surfaces.
The tubing and the gas bottle should always be
located in positions where they will not be tripped
over or otherwise inadvertently disturbed.
Before attempting to light the burner, every time
after connection, turn on the gas at the bottle and
check the gas connections for leaks by applying a
soap and water solution over them and watching for
bubbles, which would indicate a leak.
After testing dry off traces of detergent.
11.5 Connection of gas cartridge
As an option, a mobiCool Gas Kit can be
delivered. Please contact your distributor. The
instruction for use is supplied with the kit.
For your safety:
Do not check for leaks with a naked flame! Do not smoke while checking for leaks!
Figure 11.