Gas Supply G20 (2H) 20 mbar
G30/31 (3B/P)
30/30 mbar
By-pass diameters
Burner Ø By-pass in
1/100 mm.
Auxiliary 29
Burner Ø By-pass in
1/100 mm.
Semi-rapid 32
Rapid 42
Oven 44
Gas burners
Burner Normal
power
Re-
duced
power
Type of gas Pres-
sure
Injector
diameter
Usage
kW kW mbar mm g/h
Auxiliary
burner
1,00 0,35 Natural Gas
G20
20 0,70 -
1,00 0,35 Butane G30 28 - 30 0,50 72,71
0,85 0,31 Propane G31 28 - 30 0,50 60,70
Semi-
rapid
burner
2,00 0,43 Natural Gas
G20
20 0,96 -
2,00 0,43 Butane G30 28 - 30 0,71 145,43
1,70 0,38 Propane G31 28 - 30 0,71 121,40
Rapid
burner
3,00 0,72 Natural Gas
G20
20 1,19 -
3,00 0,72 Butane G30 28 - 30 0,88 218,14
2,60 0,63 Propane G31 28 - 30 0,88 185,68
Oven 2,70 0,90 Natural Gas
G20
20 1,20 -
2,70 0,90 Butane G30 28 - 30 0,80 196,33
2,35 0,78 Propane G31 28 - 30 0,80 167,82
13.3 Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with
the regulation in force. If you use flexible
metallic pipes, be careful they do not
come in touch with mobile parts or they
are not squeezed.
13.4 Flexible nonmetal pipes
connection
If it is possible to easily and fully control
the gas connection, you can use a flexible
pipe. You must tightly attach the flexible
pipe by clamps.
To install, use a pipe holder. Make sure
that you tightly attach the pipe holder to
the gasket, and then continue with the
gas connection. The flexible pipe is cor-
rect when:
It cannot become hotter than room
temperature or higher than 30 °C.
It is no longer than 1500 mm.
It does not compress.
It is not subject to traction or torsion.
It does not make contact with sharp
edges or corners.
24