Instructions for the Installer
Technical Data
Recess dimensions
Height in coloumn
580 mm
undertop
593 mm
Width
560 mm
Depth
550 mm
Oven cavity dimensions
Height
335 mm
Width
395 mm
Depth
400 mm
Volume
53 l
Oven elements
Bottom heating element 1000 W
Top heating element 800 W
Full Oven (Top+Bottom) 1800 W
Grill heating element 1650 W
Fan Oven heating element 2000 W
Oven lamp 25 W
Convection fan 25 W
Cooling fan 25 W
Maximum power rating 2050 W
Voltage tension (50 Hz) 230 V
Before proceeding to the connection of the oven make
sure that:
- the limiting valve and the domestic electrical circuit
are sufficient to support the load of the appliance (see
identification plate);
- the electrical system is equipped with an earthing
cable in accordance with current norms and legal
provisions;
- the plug or omnipolar switch used to carry out the
connection is easily accessible once the appliance
is installed.
The appliance is supplied with power cable, the
conductors of which have a minimum section of 3x1.5
mm. Besides this, the cable has a normalised plug
suitable for the electrical load indicated on the
identification plate.
The plug should be connected to a suitable elctrical
socket.
If a direct connection to the supply is desired an omnipolar
switch having a minimum opening of 3mm between the
contacts must be installed between the appliance and
the electricity supply; this switch must be suitable for
the electrical load of the appliance and must conform to
the current norms.
The yellow/green earth wire must not be interrupted by
the switch and it shouldbe 2-3 cm longer than the other
cables.
In every case the supply cable must be positioned insuch
a way that it can, at no time, reach temperaures of more
than 90°C.
After connection test the heating elements by putting
them into operation for abour 3 minutes.
The manufacturers decline all responsibility for
damage or accidents in cases where norms
have not been observed and respected.
Electrical connection
Only qualified personnel should install the appliance (place in cabinet and make electrical connection).
Every operation must be carried out with appliance disconnected from the electricity supply; when this is
not possible the maximum care is required when working on the appliance.