N.B. The default parameters (DEF.) may vary for different
appliance models.
D.6 LIST OF USER PARAMETERS
SYMBOL RANGE DEF.
MIN
Internal clock: Minutes 0..59 0
HOUR
Internal clock: Hours 0..23 0
DAY
Internal clock: Day 1..31 1
MON
Internal clock: Month 1..12 1
YEAR
Internal clock: Year 0..99 0
SrF
Indicates the chamber temperature setpoint for the positive maintenance cycle
and preservation stage after positive chilling.
-25..10°C/F 3
SFF
Indicates the chamber temperature setpoint for the negative maintenance cycle
and preservation stage after negative chilling.
-25..10°C/F -25
CdiF
Indicates whether the LAC and HAC temperature limits are expressed in
differential (d) or absolute mode (A).
A/d D
LAC
Temperature delta for preservation/absolute temperature setting under which a
low temperature alarm will be generated
-50..125°C/F 5
HAC
Temperature delta for preservation/absolute temperature setting above which a
high temperature alarm will be generated
-50..125°C/F 5
SLd
Indicates the duration of the sterilisation cycle 0..240 10
bCCy
Buzzer modes for signalling the satisfactory end of a chilling cycle Nob bbl
'nob' = buzzer off; bbl
'bbl' = buzzer on for 30 seconds; lbl
"llb" = buzzer on until any button is pressed
bFCy
Buzzer mode for signalling HACCP alarms bbl
bAll
Buzzer mode for signalling a general alarm lbl
CCEt
U.S. Standard: POSITIVE CHILLING END TEMPERATURE 0..CbSt°C/F 4
CCtI
U.S. Standard: POSITIVE CHILLING END TIME 0..360 min 240
CFEt
U.S. Standard: NEGATIVE CHILLING END TEMPERATURE -35..CbSt°C/F 4
CFtI
U.S. Standard: NEGATIVE CHILLING END TIME 0..360°C/F 240
CbSt
U.S. Standard: CHILLING START TEMPERATURE 0..127°C/F 60
tPrA
Indicates the printing interval during a chilling cycle. If set to 0 only the
temperatures at the start and end of the cycle are printed.
1..255 min 5
tPrC
Indicates the preservation/maintenance printing interval. If set to 0 no values
are printed.
1..255 min 30
Adr
Network address. 01-FF
1
E485
Connection time: Prn/PC Prn
Prn = Printer;
PC = Personal Computer;
nOr
3 values are available: nF, Uk, CuSt CuSt
nF means Electrolux Food Safe Mode 1
Uk means Electrolux Food Safe Mode 2
CuSt means U.S. Standard
REL
Software version. - -
Seitenansicht 16
1 2 ... 12 13 14 15 16 17 18 19

Kommentare zu diesen Handbüchern

Keine Kommentare