0408
12
4
D0561
15
INSTALLATION
MANUAL
Notice Date Page
05405004
4. Installation
This ironer has a an adjustable safety thermostat in order to avoid damages of the
cotton covering in case of machine stop with the bed closed.
This safety thermostat is adjusted in our plant so that the regulation thermostat
doesn’t go above the temperature corresponding to the position
which is
aproximatly 150 °C ; even when it is set on a higher temperature.
Safety Thermostat’s adjustment
If you want to increase the ironing
temperature, dismantle the bed’s back
casing and turn the rod (T) of the safety
thermostat.
This way, you can limit the maximum
ironing temperature as you want.
Fig.
15
Check-out
Before leaving, put the appliance into operation and allow to run a complete cycle.
Watch to ensure that all burner system components function correctly.