Model
Power supply
Input Rated Amp
(Switch/Fuse)
9000Btu/h
NOTE: The supply voltage should be consistent with the rated voltage of the
air conditioner.
Power Cord Size
220-240V~ 50Hz
16A
/1.5mm
2
1.0mm
2
Connect the cable to the indoor unit
1. Indoor/Outdoor connection cable should be H07RN-F type.
2. Open the panel , then remove the window cover.
3. Connect cables according to their marks to terminals.
4. Wrap those cables not connected with terminals with insulation tapes, so
that they will not touch any electrical components.
10mm
10mm
40mm
40mm
Cooling only
type.
Cooling & heating
type.
Code wire
Terminal block of indoor unit
To outdoor unit
To outdoor unit
Cord clamp
12(N)34
12(N)34
10
Electrical work
Fig.20
or
Or
10mm
40mm
Cooling & heating
type.
Window cover
Panel
Or
220-230V ~ 60Hz
16A
1.5mm
2
10000Btu/h Model 12000Btu/h
12(N)34
To outdoor unit