9406
During water inlet the timer will hold. It will restart
when the level switch opens to indicate that the
water level in the drum has been reached.
Hot and/or cold water may be programmed "Inlet".
Use the facility to reduce the heating time by
programming hot water or mixed cold and hot
water filling.
During "Heating" the timer will hold. It will restart
when the thermostat opens to indicate that the
selected temperature has been reached.
By cutting track detergent must NOT be dispensed
during heating.
Cold water enters the machine during
programming. "Cooling". This provides a cooling of
3-4°/minute.
The last punched peg in a sub routine determines
where the first one of the next sub routine should
be punched. For example, if the first rinse ends
with a spin punch in peg 38 the second rinse starts
with cold water filling peg 39.
If there are no punched pegs, the advane of the
automatic card device stops. This means a row
cannot be left unpunched during a programme, the
programme must be a complete sequence with
information about the washing process.
Programming of "Stop" can be made serveral time
during the same washing programme. When the
programme reaches the stop the buzzer sounds
and the machine stops. It is then possible to carry
out required action such as detergent dispensing.
When restart is required press the restart button
and the washing process continues in accordance
with the programme.
PLEASE NOTE
Ensure that the programme card does not come in
contact with detergent or any other substance
which could cause interference in the programme.
Detergent on the card may coat the microswitches
and can cause them to fail or may deposit a layer of
detergent on the advance reels thus increasing their
diameter. As a result, they will press the programme
card harder against the micro switches which in turn
may interpret this as the presence of a peg even
when the peg has been removed. The required
function may start later or may be completely absent.