12. Function Sequences
12
17 9108
Page
Water filling
The following conditions must be met for water valves Y14 (12), Y24 (13) or
Y34 (14) to be energised:
• Row M, stop (1) must not be programmed
• The out-of-balance switch must not have tripped (breaks K53:51-52 (2)
power supply)
• Row K, drain (3) must not be programmed
• The water level must not exceed low or high level
Level control B1 (6) has two switching contacts, 21-22 switches at low
level and 31-32 switches at high level. Which of these contacts activate
the water valves depend on whether row N, high level (5) is
programmed or not.
If the the above conditions are met, the water valves can be controlled by
programming row O, Cold water (7), row Q, Hot water (9) and Row L, Cold
hard water (11).
The water valves Y14 (12) and Y24 (13) can also be controlled manually
with the switches S36 (8) and S35 (10) on the machine control panel.