Service
Manual
9406
Data
Motor 220V 50/60Hz
Contacts, making capacity 6 (10) A 250V
(breaking capacity)
Description
The automatic unit has a time relay for drain which
prevents the spin from starting too early – the water
must have drained. When the time relay for drain is
live, the timer relay clock is set on a preselected time
and the power to the spin is cut. (The timer relay
engages peg 11 which is unconnected). The power
chain for the spin is made live when the time on the
clock has passed (peg 13 is engaged).
There is a further timer relay in the power chain of
the spin. This timer relay ensures that the high spin
speed is not connected until the low spin speed has
lasted for a certain time. When the timer relay is live
the circuit for low spin speed is connected and the
timer relay clock is set on a pre-selected time. The
circuit for high speed spin is made live when the
slelected time has passed.
Repair instructions
The timer relay should be replaced, as repair is not
recommended.
Replacing the timer relay:
1. Remove and mark the time relay connections.
2. Remove the timer relay.
3. Have the new timer relay ready and open the door
above connection terminal.
Insert plastic gear wheel to the appropriate time
interval (see table by door).
4. Turn the indicating hands to the time the relay
should be set on.
5. Install relay and connect cables.
49. Time Relay
49
1
Dial for setting time
Scale
Lock
Gear wheel
Timing relay