Service
Manual
9406
23
If the syncronised motor receives power but the motor
is not running:
– Remove the clamp which holds the motor and
check that the output shaft of the motor
revolves. (A fully synchronous motor can only
rotate in one direction.
– If the motor functions, change the driving gear.
To check the microswitches:
(A special test card is available to adjust and chek the
microswitches. The card is inserted in the automatic
card device with the coloured area facing up and on
the right. Use the edge of the opening as an
indication line).
1. Turn the automatic card device dial to position O.
2. Insert the card.
3. Turn the automatic card device dial to position 1.
4. Slowly push the card out and in and check that all
the microswitches switch off (within the two areas
on the card). It is advisable to use a buzzer for this
check.
5. If any of the microswitches need to be changed/
adjusted, remove the two screws which hold the
black protecting plate and remove the protecting
plate. If necessary, replace faulty microswitches.
6. When carrying out adjustments the test card shall
be inserted so that the white area on the card is
situated at the edge of the opening of the device.
Using the screw, adjust the microswitch so that the
screw switches to the ON position.
7. Repeat point 4 in order to check that the switch is
in the correct position.
Motor
Clamp
Gear
Adjusting screw
Protecting plateMicroswitch
2
23. Timer
Test card for microswitch
control
Kommentare zu diesen Handbüchern