Service
Manual
9406
30. Motor
4
30
Repair instructions
Overheated motor, motor not running
• Wait till motor has cooled down. Motor guards
are automatically reset after 30 minutes. Restart.
• Possible cause of motor gurads releasing
repeatedly: short circuiting. In both cases the
motor should be replaced.
Very noisy motor
• Breakdown of bearings – replace motor.
Motor running slowly
The motor is probably running on two phases –
measure coils on terminal.
Wash motor only runs at one of the speeds
• Check that the quick connection is correctly
connected.
• Measure coils on plinth, as the fault can be
caused by interruption in one of the coils.
Motor locks
Breakdown of bearings – replace motor
Motor does not turn
• Check belt tension.
When checking the belt tension or when changing
belt, follow the instructions shown.
NOTE!
Checking the belt tension should always be a
part of the regular maintenance.
FLE/FLE MP
• Belt between the wash motor and extraction
motor. Release and adjust backing plate to
correct belt tension according to illustration.
Fasten plate.
• Belt between extraction motor and wash drum.
Remove screws for the attachment of motor
bridge at extraction motor side, lower motor
bridge to correct belt tension according to
illustration and fasten bridge.
120 220
F 30 N 30 N
A
max
12 mm 12 mm
A
min
10 mm 10 mm
2311
A
F
2434
5
4
FLE MP FC
FLE/FLE MP
Fig.
4
Fig.
5
Kommentare zu diesen Handbüchern