If you have nonstick accessories, do
not clean them using aggressive
agents, sharp-edged objects or a dish-
washer. It can cause damage to the
nonstick coating.
12.1 Pyrolytic cleaning
1.
Remove the removable shelf supports
(if applicable) and accessories from
the appliance.
The pyrolytic cleaning proce-
dure cannot start:
If you do not remove the core tem-
perature sensor plug from the
socket.
If you do not close the appliance
door correctly.
2.
Remove the worst dirt manually.
3.
Clean the inner side of the door with
hot water to avoid any residue burn-
ing in because of hot air.
4.
Activate the appliance and set the Py-
rolysis function in the main menu.
Press OK to confirm.
5.
Set the duration of the cleaning pro-
cedure:
Quick – 1 h for a low degree of dirt
Normal – 1 h 30 min for a usual
degree of dirt
Intense – 2 h 30 min for a high de-
gree of dirt.
6.
Touch OK to confirm.
When the pyrolytic cleaning starts,
the appliance door is locked. After
the function is completed, the
door stays locked for the cool
down phase. Some of the appli-
ance functions are not available
during the cool down phase.
WARNING!
After the function is completed,
the appliance is very hot. Let it
cool down. There is a risk of
burns.
12.2 Shelf supports
Removing the shelf supports
You can remove the shelf supports to
clean the side walls.
1.
Pull the front of the shelf support
away from the side wall.
1
2
2.
Pull the rear end of the shelf support
away from the side wall and remove
it.