Dimensions
Weight
Capacity (water temp. 15 °C)
Water efficiency
Electrical supply
Total power consumption
Operation period
Sound level when installed in under-sink cupboard
Environmental specifications
air temperature
relative humidity
Salt (total dissolved solids: TDS) reduction
Chlorine reduction
Requirements of feed water to the RO 400:
Water flow
Domestic water supply pressure
Water temperature
Chemical requirements:
conductivity
/salt
/chloride
cloudiness
turbidity
pH
calcium: Ca
2+
magnesium: Mg
2+
/hardness: CaCO
3
iron: Fe
2+
iron: Fe
3+
manganese: Mn
COD-Mn: O
2
* higher values require an extra prefilter
height 1 ft 6 3/8” (466 mm)
depth 1 ft 6 1/8” (460 mm) 1 ft 3 1/2” (395) mm
without hand-grip and hoses
width 8 7/8” (225 mm)
64 lbs (29 kg) when supplied
73 lbs (33 kg) when filled with water
0,8±0,1 gallon/minute (3.1 ±0.4 litres/minute)
approx. 80 % at constant flow
approx. 50 - 75 % including flushing
115 V, 60 Hz, earthed socket
530 W
20 minutes
< 60 dB(A)
39 - 109 °F (2 - 43 °C)
25 – 95 %
> 90%
> 99%
> 2,6 gpm (>10 l/min)
22 - 145 psi (150 - 1000 kPa)
36 - 104 °F (2 - 40 °C)
<200 mS/m
<1500 mg/l
<900 mg/l
slight/ distinct*
< 1 FNU
4 - 10
<140 mg/l
<350 mg/l
<5 mg/l*
<0.30 mg/l *
<0.8 mg/l*
<10 mg/l